Validation

Question. Does zvCFD solve the equations it claims to solve? How fast does its error fall as the grid is refined? And on a real case, does it give the same answer as an established solver?

The evidence comes in three layers, from the most controlled to the most realistic:

Layer

Page

Reference

What it establishes

Finite-volume solver (the main solver), validated on meshes that fit one GPU

Finite-volume solver

exact, manufactured and benchmark solutions on unstructured meshes; OpenFOAM on the same mesh

the numbers: orders, errors, invariances, GPU agreement, defects found

Verification and validation

the V&V evidence for the CFX-style solver, by ASME V&V 20 / 40 layer

what is established, prepared and missing

Against SimVascular

SimVascular’s published results, on SimVascular’s own mesh

the same pulsatile flow, velocity and wall shear stress through a whole cardiac cycle

Turbulent flow

NASA Turbulence Modeling Resource cases (flat plate, NACA 0012); independent solvers of the same equations; Ladson’s and Gregory & O’Reilly’s experiments

the k-kL model: skin friction, velocity profiles, lift, drag and surface pressure

Lattice-Boltzmann solver: exact solutions

Exact solutions

closed-form solutions of the Navier–Stokes equations

the equations are solved, and to what order of accuracy

Lattice-Boltzmann solver: standard benchmarks

Standard benchmarks

literature reference values (Sangani & Acrivos; Schäfer & Turek)

accuracy on porous-media drag and on forces on a curved body

Lattice-Boltzmann solver: cross-code comparison

Against OpenFOAM

OpenFOAM v2506 on the same problems

the same answers on identical voxel geometries and on the HiP-CT coronary tree

Against SimVascular

SimVascular’s published results for a patient coronary model (VMR 0066_H_CORO_H)

the same pulsatile flow, velocity and wall shear stress through a whole cardiac cycle

The lattice-Boltzmann cases use the production kernels: D3Q19, TRT with Λ = 3/16, fp32 arithmetic on shifted populations, half-way bounce-back walls, Guo forcing and Guo non-equilibrium-extrapolation inlets and outlets. The exact and reference solutions are in benchmarks/validation/exact.py, independent of the solver. The cases themselves are in benchmarks/validation/cases.py, raw results in benchmarks/results/validation/, and fast versions run in the test suite (tests/test_validation.py).


Finite-volume solver: summary

The finite-volume solver is validated on meshes that fit one GPU. The numbers are on Finite-volume solver; the evidence is organised by ASME V&V 20 / 40 layer on Verification and validation.

Evidence

Result

Manufactured solutions and exact Navier–Stokes flows (Kovasznay, Womersley, Ethier–Steinman), unstructured and warped meshes

velocity second order; BDF2 second order in time

DFG 2D-1 cylinder (Schäfer & Turek)

drag coefficient +0.23 %, pressure drop +0.35 % (21,680 nodes)

Lid-driven cavity, Re = 100 and 400 (Ghia et al.)

centreline velocity RMS 0.003–0.007 at 64²

Developed pipe flow against OpenFOAM on the same mesh

zvCFD 0.5–0.7 % from the exact flow rate, OpenFOAM 5.8–6.8 %

Wall shear stress (CFX’s wall-gradient method)

exact for linear fields on every element type; within 2 % of Poiseuille with prism layers at R/32

SimVascular coronary model, one cardiac cycle, SimVascular’s mesh

outlet flows 0.5 % (2.2 % max), velocity 1.3–1.8 %, TAWSS 3.1 % (Against SimVascular)

k-kL turbulence model, NASA flat plate (Re = 5 million)

c_f(0.97) grid-converged 1 % above CFL3D and FUN3D with the same model, 0.26 % normalised by each code’s edge velocity; peak eddy viscosity within 1 % (Turbulent flow)

k-kL turbulence model, NACA 0012 (Re = 6 million, α = 0–15°)

on the 225 × 65 grid surface pressure and skin friction on CFL3D’s with the same model; lift 2.6–3.0 % low and drag 5–15 % high against CFL3D, FUN3D and TAU on 897 × 257, converging towards them (Turbulent flow)

Pending: the HiP-CT coronary tree against the collaborator’s Ansys CFX run (the main target; it needs an H100), coronary runs at H100 scale, scaling across GPUs, and DFG 2D-2 (vortex shedding).

Lattice-Boltzmann solver: summary

Case

Reference

Exercises

Error on the finest grid

Observed order

Plane Poiseuille, body force, τ = 0.55–2

exact

walls, forcing, τ-independence

3 × 10⁻⁷ – 4 × 10⁻⁵

exact to round-off

Plane Poiseuille, pressure patches, τ = 0.6–2

exact

pressure boundaries

3 – 7 × 10⁻⁶

exact to round-off

Square duct

series (White)

3-D walls

7.9 × 10⁻⁵ (62 cells across)

2.0

Womersley channel, α = 4 / 12

exact (Womersley)

pulsatile flow, time accuracy

4.1 × 10⁻⁵ / 2.2 × 10⁻⁴

2.1 / 2.5

Taylor–Green vortex

exact Navier–Stokes

nonlinear terms, pressure

velocity 3.6 × 10⁻⁵, pressure 9.4 × 10⁻⁴ (128²)

2.0 / 2.0

Carreau–Yasuda channel (blood exponents)

exact (stress balance)

shear-thinning rheology

1.6 × 10⁻⁴

2.3

Hagen–Poiseuille pipe

exact

curved walls (staircase)

4.9 × 10⁻³; flux −0.15 % (64 cells across)

1.2

Womersley pipe, α = 4 / 12

exact (Bessel)

pulsatile flow, curved walls

6.2 × 10⁻³ / 1.6 × 10⁻²

1.3 / 1.2

Simple cubic array of spheres, φ = 0.004–0.38

Sangani & Acrivos

porous-media drag

within 2.0 % (64³ cell); matches a published TRT code

—

Cylinder in a channel, Re = 20 (DFG 2D-1)

Schäfer & Turek

drag, lift, Δp on a curved body

drag +0.9 to +1.9 %, lift ±2 %, Δp ±1.4 % (40–80 cells across)

— (staircase and Mach)

Voxel ducts, pipes, porous sample, vessel network

OpenFOAM v2506, same voxels

whole solver, pressure-driven

fluxes agree within 1.1 % (2.6 % in the coarsest pipe)

—

HiP-CT coronary tree, 77 outlets

OpenFOAM v2506, 14.8 M-cell body-fitted mesh

whole pipeline from the Fluent mesh

see Against OpenFOAM

—

VMR coronary trees, 24 outlets, pulsatile

SimVascular (svSolver), 3.8 M tetrahedra

whole pipeline from a SimVascular surface, a full cardiac cycle

lattice Boltzmann (60 µm): outlet flows 1.3 % on average (4.2 % max), pressure drop +0.4 / +2.8 %, velocity 5.4 %, TAWSS 5.8 %; finite volume (SimVascular’s mesh): outlet flows 0.5 % (2.2 % max), pressure drop +1.0 / +1.9 %, velocity 1.6 %, TAWSS 3.1 % (own method 3.7 %)

— (see Against SimVascular)

Errors are relative L2 norms over the fluid (or over a period, for the pulsatile cases) unless stated. The Taylor–Green orders are the velocity from an equilibrium start and the pressure from a consistent start (see Exact solutions).

Convergence under grid refinement

Where the walls lie on lattice planes, or there are none, zvCFD is second-order accurate. This holds in space and time, for steady and pulsatile flow, for the nonlinear Navier–Stokes terms and for the shear-thinning rheology. Plane Poiseuille flow is reproduced exactly (to fp32 round-off) at every τ tried, the defining property of TRT with Λ = 3/16.

Curved walls are first order, because a voxel wall is a staircase: flux errors in a pipe fall from 4 % at 8 cells across to 0.15 % at 64. This is the known limit of half-way bounce-back, and the reason interpolated bounce-back is on the roadmap. By this test a straight vessel needs about 30 voxels across for its flow to be accurate to 1 %. In the coronary tree at 50 µm, the smallest outlets are 5 voxels across and the inlet is 31.

Porous-media drag is within 2 % of the analytic result for regular sphere arrays on a 64³ cell. zvCFD reproduces a published TRT code’s errors point by point.

Defects the validation found

Validation is only useful if it can fail. It did, five times, and each defect is fixed in the numbers on these pages:

Found by

Defect

Symptom

Fix

OpenFOAM comparison, τ scan

fp32 arithmetic on full populations

steady fluxes wandered ±0.1 % for 50,000 steps and drifted with τ by up to 12 %

store and compute f − w (shifted populations)

Force-driven channel

velocity output added half the body force instead of subtracting it

a velocity offset of exactly F: 3 % at τ = 2

u = (Σ f* c − F/2)/ρ from post-collision populations

Carreau–Yasuda channel

3 fixed-point iterations for the local viscosity

0.6 % profile error that did not fall with resolution

iterate until ω settles (10⁻⁶, at most 12)

Porous sample, τ scan

pressure patches cutting through a porous face

flux varied 7 % with τ

documented; open buffer layers at the ends bring it under 1 %

SimVascular comparison; straight pipe

non-equilibrium-extrapolation pressure patches where the flow crosses them off the lattice axes, at low τ

a pressure jump at each coronary outlet (5–110 Pa); up to 17 % of Δp lost in an oblique pipe at τ = 0.55; the unexplained dominant-outlet gap against OpenFOAM

pressure outlets on caps as anti-bounce-back on the links that cross the cap: under 1.5 % per patch at any orientation and τ (Against SimVascular)

Two further problems were in the reference software or the test harness, not the solver. The conda-forge build of OpenFOAM v2412 under-predicts laminar duct flow by 19 %; the official images are exact (Against OpenFOAM). And a Taylor–Green start without a consistent pressure divergence launches a sound wave that makes the pressure look first-order accurate.

What is not validated yet

  • Moving walls (Couette flow, the lid-driven cavity of Ghia et al. 1982): zvCFD has no moving-wall boundary condition.

  • Turbulence and transition (the 3-D Taylor–Green vortex at Re = 1600, the DFG 2D-2 vortex street): outside the MVP’s laminar scope.

  • The HiP-CT coronary tree’s total resistance: zvCFD’s inlet pressure is 4–5 % below OpenFOAM’s, closing slowly with refinement (Against OpenFOAM). The splits agree to 0.01 pp.

  • Velocity inlets on oblique caps still use non-equilibrium extrapolation. Flow control makes their flow exact, and the SimVascular comparison shows no inlet pressure step, but they are not tested apart from that.

  • Against Ansys CFX on the collaborator’s case: the cross-code comparison uses OpenFOAM; the CFX run is the next validation target.

  • Double precision: every case runs in fp32. Where a result reaches an error floor (about 10⁻⁵), that floor is fp32.

Reproducing

python benchmarks/validation/run.py                  # all cases, ~15 min on an RTX A2000
python benchmarks/validation/figures.py
pytest tests/test_validation.py                      # the fast subset

The cross-code comparison has its own instructions on Against OpenFOAM.