Against OpenFOAM

The exact solutions test the solver one mechanism at a time. A cross-code comparison tests the whole pipeline on the problem it is meant for. Here zvCFD is compared with OpenFOAM v2506 (the official opencfd/openfoam-default:2506 image, laminar simpleFoam) on two kinds of problem:

  • identical voxel geometries, where the two solvers see exactly the same staircase walls;

  • the HiP-CT coronary tree, where OpenFOAM runs on the collaborator’s body-fitted 14.8 M-cell mesh and zvCFD on voxels made from the same mesh’s surface.

Speed is reported on OpenFOAM comparison; this page is about the answers.

Two different methods cannot give byte-identical results, and should not be expected to. zvCFD is a lattice-Boltzmann method on voxels. OpenFOAM is a finite-volume method on a mesh. Each has its own discretisation error, and they converge to the same solution only as both grids are refined. Agreement is therefore judged against tolerances. Byte identity is the right test only for reproducibility, within one code on one platform (see Reproducibility).


Identical voxel geometries

Steady pressure-driven Stokes flow, the same voxels for both codes (OpenFOAM’s mesh is the fluid voxels themselves: blockMesh followed by subsetMesh). Full setup on OpenFOAM comparison.

Case

Fluid cells

Flux, zvCFD / OpenFOAM

zvCFD vs analytic

OpenFOAM vs analytic

square duct, 16 across

32,768

0.989

+0.37 %

+1.50 %

square duct, 32 across

262,144

0.997

+0.09 %

+0.38 %

pipe, radius 6

10,752

0.974

−4.2 %

−1.6 %

pipe, radius 12

86,016

0.993

−1.9 %

−1.2 %

pipe, radius 24

692,736

0.998

−1.0 %

−0.8 %

porous sample

1,042,190

1.010

—

—

vessel network

1,315,097

0.990

—

—

The two codes agree within 1.1 %, except in the coarsest pipe (2.6 %). Where an exact solution exists (the ducts), zvCFD is the closer of the two. For the pipes, “analytic” is Poiseuille flow in the circle with the voxel disk’s area. That is only a reference, because a staircase wall has no single equivalent radius.

The HiP-CT coronary tree

Steady laminar flow of Newtonian blood (ν = 3.5 × 10⁻⁶ m²/s) at 0.194 mL/s into the inlet (Re ≈ 45), with 0 Pa at all 77 outlets. OpenFOAM ran 500 SIMPLE iterations on 16 cores, by which point the splits changed by 0.0016 percentage points (pp) per 100 iterations. zvCFD ran at 50 µm (5.0 M fluid voxels) and 35 µm (14.7 M, about the mesh’s cell count), each converged to a flux change below 10⁻⁴ with inflow equal to outflow to 10⁻⁴.

OpenFOAM

zvCFD 50 µm

zvCFD 35 µm

inlet pressure

65.7 Pa

62.7 Pa (−4.6 %)

63.1 Pa (−4.0 %)

mean |split difference| over 77 outlets

—

0.009 pp

0.007 pp

largest |split difference|

—

0.11 pp

0.07 pp

largest outlet (cor_outlet_074)

31.9 %

31.9 %

31.8 %

next four outlets

10.2, 7.7, 7.5, 6.8 %

10.3, 7.8, 7.6, 6.8 %

10.2, 7.8, 7.6, 6.8 %

Outlet flow splits

The two codes split the flow between the 77 outlets identically, to 0.01 percentage points on average and 0.1 at most, at both resolutions. zvCFD’s own splits move by 0.004 pp on average between 50 and 35 µm.

The inlet pressure, which measures the tree’s total resistance, is 4–5 % lower in zvCFD. OpenFOAM’s inlet pressure had settled, to 65.737 Pa from iteration 300 on, so the gap is not its convergence. zvCFD’s closes slowly with refinement (62.7 → 63.1 Pa), which points to discretisation. The likely source is the staircase walls of the smallest branches, which are 5 voxels across at 50 µm. Finer runs on the H100 node, or interpolated bounce-back, would settle it.

Before the outlet fix

The numbers above are from 2026-09-30, after zvCFD’s pressure outlets moved from non-equilibrium extrapolation on patch voxels to an anti-bounce-back condition on the lattice links that cross each cap (Against SimVascular). Before that, this comparison had an unexplained difference at the dominant outlet:

OpenFOAM

zvCFD 50 µm, before

zvCFD 35 µm, before

inlet pressure

65.7 Pa

65.6 Pa

67.4 Pa

mean |split difference|

—

0.08 pp

0.15 pp

largest outlet (cor_outlet_074)

31.9 %

29.9 %

27.2 %

The gap at outlet 074 grew with refinement and moved by up to 1.3 pp with τ. A badly voxelised outlet, backflow, the inlet profile and compressibility were ruled out.

The cause was the outlets. The old condition lost part of the imposed pressure wherever the flow crossed a patch off the lattice axes, the more so as τ approached ½. That added a different spurious resistance at each of the 77 outlets. The near-agreement of the inlet pressure at 50 µm was partly that extra resistance offsetting the lower resistance now measured.

Reproducibility

Which results should be byte-identical, and are they? Each claim below was tested.

Comparison

Byte-identical?

Measured

zvCFD, the same run repeated (same code, same GPU)

yes

every field chunk of every snapshot, every monitored flow and patches.csv. Only the run id and the wall-clock timings differ (tests/test_reproducibility.py)

zvCFD on 1 GPU vs split across partitions

yes

bit-identical fields (tests/test_physics.py)

zvCFD on different GPU models or drivers

not guaranteed

kernels are compiled per architecture, and instruction selection can change the last bit; compare with a tolerance (10⁻⁶ relative is ample)

OpenFOAM, the same run repeated, scotch decomposition

no

scotch cut the mesh differently on all 16 processors; the histories differ from the first iteration (second pressure residual 0.1330 vs 0.1351) and the runs stop at 1,506 and 1,505 iterations; the converged flux agrees to 3.4 × 10⁻⁹

OpenFOAM, the same run on the same decomposition

yes

U, p and φ on all 16 processors, and the flux history

OpenFOAM on 16 ranks vs serial

no

converged flux agrees to 6.8 × 10⁻⁹ (the solver tolerance)

zvCFD vs OpenFOAM

no, by construction

agreement within the tolerances above

zvCFD is deterministic by design. Every cell is updated independently, so the order of floating-point operations is fixed. The one reduction that feeds back into a run, the per-patch flux behind flow-rate control, is summed on the host in a fixed order: GPU atomic additions happen in no fixed order and could change the last bit between runs.

For a validation dataset this means:

  • Store each reference quantity with a tolerance, and judge agreement across codes, versions and hardware against that tolerance.

  • Byte identity is a regression check for one code on one platform. It is worth keeping (a SHA-256 of each field chunk costs nothing), but record the code version, GPU model, driver and, for OpenFOAM, the decomposition with it.

  • To make OpenFOAM runs byte-reproducible, keep the decomposed case (processor*/constant), or use a deterministic decomposition method (simple or hierarchical) instead of scotch.

Reproducing

The commands are on OpenFOAM comparison; the byte-identity checks are pytest tests/test_reproducibility.py.