Credits and citing

zvCFD is built on other people’s work. This page says what, and how to cite it. References lists every source behind the documentation.

Citing zvCFD

Cite the software with the repository’s CITATION.cff (GitHub’s Cite this repository button reads it):

Keenlyside, A. zvCFD: GPU-based computational fluid dynamics backed by
Zarr Vectors (version 0.0.1.dev0). https://github.com/Andrew-Keenlyside/zvCFD

Then cite what your results depend on, from the tables below.

Foundations

Work

What zvCFD uses

Cite

Zarr Vectors / zarr-vectors-py (Allen Institute; A. Keenlyside, F. Collman; BSD-3)

every brick store, written through zarr_vectors.building; GPU decode

the repository

OME-NGFF RFC-8 Collections, RFC-5 coordinate systems

the run collection layout

the RFCs

zarr-python, CuPy, NumPy, SciPy, PyAMG

arrays, GPU kernels, CPU numerics, the lubrication solve

Software

NVIDIA AmgX (BSD-3), built from source and called through a thin ctypes binding

the finite-volume solver’s algebraic multigrid (zvcfd.fv.linear)

M. Naumov et al., AmgX: a library for GPU accelerated algebraic multigrid and preconditioned iterative methods, SIAM J. Sci. Comput. 37, S602 (2015)

Methods

The solver is a clean-room implementation from the literature (policy); each kernel names the equations it implements.

Method

Source

Lattice-Boltzmann method, pull streaming

Krüger et al., The Lattice Boltzmann Method, Springer (2017)

BGK collision; D3Q19 lattice

Bhatnagar, Gross & Krook (1954); Qian, d’Humières & Lallemand (1992)

TRT collision, magic parameter Λ = 3/16

Ginzburg & d’Humières (2003); Ginzburg, Verhaeghe & d’Humières (2008)

Body forcing

Guo, Zheng & Shi, Phys. Rev. E 65, 046308 (2002)

Inlet and outlet patches (non-equilibrium extrapolation)

Guo, Zheng & Shi, Chinese Physics 11, 366 (2002)

Pressure outlets on caps (anti-bounce-back on the crossing links)

Ginzburg, Verhaeghe & d’Humières, Commun. Comput. Phys. 3, 427 (2008); Krüger et al. (2017), ch. 5

Interpolated (sub-voxel) walls, on the roadmap

Bouzidi, Firdaouss & Lallemand (2001)

Consistent initial conditions

Mei, Luo, Lallemand & d’Humières (2006)

Carreau–Yasuda blood rheology, default parameters

Cho & Kensey (1991)

16-bit population storage

Lehmann et al. (2022)

Smoothed-aggregation multigrid

Vaněk, Mandel & Brezina (1996)

Element-based finite volumes (finite-volume solver)

Schneider & Raw, Numer. Heat Transfer 11, 363 (1987)

Rhie–Chow pressure–velocity coupling; its time-step-independent form

Rhie & Chow, AIAA J. 21, 1525 (1983); Choi, Numer. Heat Transfer B 36, 545 (1999)

High Resolution limiter

Barth & Jespersen, AIAA paper 89-0366 (1989)

Additive-correction multigrid

Hutchinson & Raithby (1986); Raw, AIAA paper 96-0297 (1996); Notay (2010)

Flexible GMRES

Saad, SIAM J. Sci. Comput. 14, 461 (1993)

SIMPLE-type block preconditioner

Patankar (1980); Elman, Silvester & Wathen (2014)

Backflow stabilisation

Esmaily Moghadam et al., Comput. Mech. 48, 277 (2011)

Open-loop coronary and RCR outlets

Kim et al., Ann. Biomed. Eng. 38, 3195 (2010); Westerhof et al. (2009)

TAWSS, OSI, RRT

He & Ku (1996); Himburg et al. (2004)

Validation

Case

Source

Plane and pipe Poiseuille, square duct

White, Viscous Fluid Flow (2006)

Pulsatile pipe flow

Womersley (1955)

Decaying vortices

Taylor & Green (1937)

Periodic sphere arrays

Sangani & Acrivos (1982); Bogner, Mohanty & Rüde (2015)

Flow past a cylinder (DFG 2D-1, 2D-2)

Schäfer & Turek (1996); John & Matthies (2001)

Kovasznay flow; Ethier–Steinman flow

Kovasznay (1948); Ethier & Steinman (1994)

Lid-driven cavity

Ghia, Ghia & Shin (1982)

Solution verification (GCI)

Roache (1994); Celik et al. (2008)

Comparisons and data

  • OpenFOAM (ESI OpenFOAM v2506, OpenCFD Ltd., GPL-3.0) is run as a separate program for the OpenFOAM benchmarks; zvCFD contains none of its code. OpenFOAM is a trademark of OpenCFD Ltd.; zvCFD is not approved or endorsed by OpenCFD.

  • SimVascular (Updegrove et al. 2017) results for model 0066_H_CORO_H come from the Vascular Model Repository: Wilson, Ortiz & Johnson, J. Med. Devices 7(4):040923 (2013), doi:10.1115/1.4025983; data doi:10.25740/dh173bw0673. Its coronary outlet conditions follow Kim et al., Ann. Biomed. Eng. 38, 3195 (2010). The data used herein was provided in whole or in part with Federal funds from the National Library of Medicine under Grant No. R01LM013120, and the National Heart, Lung, and Blood Institute, National Institutes of Health, Department of Health and Human Services, under Contract No. HHSN268201100035C.

  • The HiP-CT coronary geometry was imaged by hierarchical phase-contrast tomography at the ESRF (Walsh et al., Nat. Methods 18, 1532 (2021)), and segmented and meshed in Simpleware ScanIP by a collaborator. It is not redistributed.

  • Published performance figures (FluidX3D, waLBerla, XLB, Palabos, HemeLB, Ansys, STAR-CCM+ and others) are cited where they are used and listed with their provenance.

Trademarks

Ansys, Fluent and CFX are trademarks of ANSYS, Inc.; STAR-CCM+ of Siemens; NVIDIA, CUDA and H100 of NVIDIA Corporation. They are named for comparison only.